The HSD820H3PRH is not pressurized at the factory.

Complete the following steps to pressurize the camera before you install it.

Step 1:

Set the gauge or regulator from 10 to 20 psi (0.7 to 1.4 bar).

                                                                             

 

Step 2:

Place the air chuck on the tank valve and begin filling until the pressure relief valve opens.

                                                                                  

 

Step 3:

Open the relief valve. Drain all air from the housing and repeat three times to remove all moisture.

                                                                                 

 

Step 4:

After purging check the housing pressure. It should be around 5 psi (0.34 bar).

                                                                                   

 

 

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request